MontgomeryDivisorDataPool.Rent / .Return removed as we no longer pool Montgomery divisor data. UInt128Extensions.MontgomeryDivisorDataPool variables optimized.

This commit is contained in:
mlemanczyk committed 2025-12-16 02:27:29 +01:00
1 parent b7773adad8
commit 3c80221105
27 files changed
+260 -476

No files matched your search

@@ -49,17 +49,17 @@ public class MersenneNumberDivisorCpuTesterTests
{
ulong[] primes = [5UL, 7UL, 11UL, 13UL];
ulong cycle23 = MersenneDivisorCycles.CalculateCycleLengthCpu(23UL, MontgomeryDivisorDataPool.Shared.FromModulus(23UL));
session.CheckDivisor(23UL, MontgomeryDivisorDataPool.Shared.FromModulus(23UL), cycle23, primes).Should().BeTrue();
ulong cycle23 = MersenneDivisorCycles.CalculateCycleLengthCpu(23UL, MontgomeryDivisorData.FromModulus(23UL));
session.CheckDivisor(23UL, MontgomeryDivisorData.FromModulus(23UL), cycle23, primes).Should().BeTrue();
ulong[] primesWithoutHit = [5UL, 7UL, 13UL];
session.CheckDivisor(23UL, MontgomeryDivisorDataPool.Shared.FromModulus(23UL), cycle23, primesWithoutHit).Should().BeFalse();
session.CheckDivisor(23UL, MontgomeryDivisorData.FromModulus(23UL), cycle23, primesWithoutHit).Should().BeFalse();
ulong cycle31 = MersenneDivisorCycles.CalculateCycleLengthCpu(31UL, MontgomeryDivisorDataPool.Shared.FromModulus(31UL));
session.CheckDivisor(31UL, MontgomeryDivisorDataPool.Shared.FromModulus(31UL), cycle31, primes).Should().BeTrue();
ulong cycle31 = MersenneDivisorCycles.CalculateCycleLengthCpu(31UL, MontgomeryDivisorData.FromModulus(31UL));
session.CheckDivisor(31UL, MontgomeryDivisorData.FromModulus(31UL), cycle31, primes).Should().BeTrue();
ulong[] primesBeforeHit = [7UL, 11UL, 13UL];
session.CheckDivisor(31UL, MontgomeryDivisorDataPool.Shared.FromModulus(31UL), cycle31, primesBeforeHit).Should().BeFalse();
session.CheckDivisor(31UL, MontgomeryDivisorData.FromModulus(31UL), cycle31, primesBeforeHit).Should().BeFalse();
}
finally
{
@@ -81,7 +81,7 @@ public class MersenneNumberDivisorCpuTesterTests
{
ulong[] exponents = [6UL, 7UL, 9UL, 10UL, 12UL];
MontgomeryDivisorData divisorData = MontgomeryDivisorDataPool.Shared.FromModulus(7UL);
MontgomeryDivisorData divisorData = MontgomeryDivisorData.FromModulus(7UL);
ulong cycle = MersenneDivisorCycles.CalculateCycleLengthCpu(7UL, divisorData);
session.CheckDivisor(7UL, divisorData, cycle, exponents).Should().BeTrue();
@@ -108,7 +108,7 @@ public class MersenneNumberDivisorCpuTesterTests
{
ulong[] exponents = [10UL, 11UL, 20UL, 21UL, 30UL];
MontgomeryDivisorData divisorData = MontgomeryDivisorDataPool.Shared.FromModulus(11UL);
MontgomeryDivisorData divisorData = MontgomeryDivisorData.FromModulus(11UL);
ulong cycle = MersenneDivisorCycles.CalculateCycleLengthCpu(11UL, divisorData);
session.CheckDivisor(11UL, divisorData, cycle, exponents).Should().BeTrue();